Table 4
Results of ICN-JFK Flights on 16 November and 19 September 2019 and comparison with Liulin spectrometer

dD/dt (μGy/h) Mean Q dH*(10)/dt (μSv/h) Average dH*(10)/dt (μSv/h) Cfield
2019-11-16, ICN-JFK route
SRDAS101 2.66 ± 0.24 2.90 7.40 ± 3.59 7.69 ± 0.08 2.68
SRDAS103 2.47 ± 0.31 3.14 7.83 ± 4.45
Liulin-MDU2 2.84 ± 0.25 - 10.06 ± 1.42 10.31 ± 0.43
Liulin-MDU3 2.93 ± 0.33 - 10.64 ± 1.94

2019-11-23, JFK-ICN route
SRDAS101 2.50 ± 0.24 3.09 7.92 ± 3.45 7.58 ± 0.2 2.83
SRDAS103 2.24 ± 0.21 3.31 6.80 ± 2.84
Liulin-MDU2 2.60 ± 0.26 - 8.84 ± 1.39 9.26 ± 0.34
Liulin-MDU3 2.72 ± 0.26 - 9.44 ± 1.44
ICN, Incheon airport; JFK, John F. Kennedy airport; SRDAS, space radiation dosimeter for aviation safety.